1.What is the total equivalent power class of the APS 3200 APU?
- A.About 150 kW
- B.About 1,000 kW
- C.About 400 kW
Show answer and explanation
Correct answer: C. About 400 kW
The APS 3200 is in the 400 kW (536 hp) total equivalent power class and weighs about 136 kg. Ref Lufthansa A319/A320/A321 APS 3200 training manual, ATA 49.
2.On the APS 3200, which load has priority when the APU is near its limit?
- A.Bleed air load
- B.Whichever came first
- C.Electrical load
Show answer and explanation
Correct answer: C. Electrical load
Electrical power always has priority; bleed air is reduced to protect the APU against overload. Ref Lufthansa A319/A320/A321 APS 3200 training manual, ATA 49.
3.Up to what altitude can the APS 3200 supply both bleed air and electrical power?
- A.39,000 ft
- B.20,000 ft
- C.15,000 ft
Show answer and explanation
Correct answer: B. 20,000 ft