1.What type of generator are the 777 backup generators?
- A.An IDG type, at constant speed
- B.A constant-frequency AC type
- C.Variable speed and frequency
Show answer and explanation
Correct answer: C. Variable speed and frequency
The backup generators are variable-speed, variable-frequency; the backup converter turns their output into 400 Hz power. Ref AMM 24-00-00.
2.With the standby power switch at OFF, when does the static inverter stay off?
- A.On the ground
- B.In the air
- C.At all times
Show answer and explanation
Correct answer: A. On the ground
The OFF position keeps the static inverter off on the ground. Ref AMM 24-00-00.
3.How do the P110 and P210 power management panels shed loads?
- A.Alone or together, as sources allow
- B.Always independently of each other
- C.Always together as one system
Show answer and explanation
Correct answer: A. Alone or together, as sources allow
They can shed loads on their own or operate together, depending on which power sources are available. Ref AMM 24-09-00.