  1. 1.What is the rated output of each A320 engine-driven generator?

    • A.115/200 V, 3-phase, 400 Hz, 90 kVA
    • B.115/200 V, 3-phase, 400 Hz, 60 kVA
    • C.28 V DC, 400 A, single channel
    Show answer and explanation

    Correct answer: A. 115/200 V, 3-phase, 400 Hz, 90 kVA

    Both IDG generators and the APU generator give 115/200 V three-phase 400 Hz AC at 90 kVA.

  2. 2.What is the rated output of the A320 emergency generator (CSM/G)?

    • A.1 kVA
    • B.90 kVA
    • C.5 kVA
    Show answer and explanation

    Correct answer: C. 5 kVA

    The RAT-powered Constant Speed Motor/Generator gives 115/200 V, 400 Hz, 5 kVA continuously.

  3. 3.How does the A320 emergency generator get its drive?

    • A.Its own small air turbine in the RAT
    • B.A gearbox on the APU
    • C.A hydraulic motor on the blue system
    Show answer and explanation

    Correct answer: C. A hydraulic motor on the blue system

    The CSM/G is a hydraulic motor driving a generator, fed from the blue system that the RAT pressurizes.